109 research outputs found

    Minor head trauma in infants - how accurate is cranial ultrasound performed by trained radiologists?

    Get PDF
    Correct management of infants after minor head trauma is crucial to minimize the risk to miss clinically important traumatic brain injury (ciTBI). Current practices typically involve CT or in-hospital surveillance. Cranial ultrasound (CUS) provides a radiation-free and fast alternative. This study examines the accuracy of radiologist-performed CUS to detect skull fracture (SF) and/or intracranial hemorrhage (ICH). An inconspicuous CUS followed by an uneventful clinical course would allow exclusion of ciTBI with a great certainty. This monocentric, retrospective, observational study analyzed CUS in infants (< 12 months) after minor head trauma at Bern University Children's Hospital, between 7/2013 and 8/2020. The primary outcome was the sensitivity and specificity of CUS in detecting SF and/or ICH by comparison to the clinical course and to additional neuroimaging. Out of a total of 325 patients, 73% (n = 241) had a normal CUS, 17% (n = 54) were found with SF, and ICH was diagnosed in 2.2% patients (n = 7). Two patients needed neurosurgery and three patients deteriorated clinically during surveillance. Additional imaging was performed in 35 patients. The sensitivity of CUS was 93% ([0.83, 0.97] 95% CI) and the specificity 98% ([0.95, 0.99] 95% CI). All false-negative cases originated in missed SF without clinical deterioration; no ICH was missed.  Conclusion: This study shows high accuracy of CUS in exclusion of SF and ICH, which can cause ciTBI. Therefore, CUS offers a reliable method of neuroimaging in infants after minor head trauma and gives reassurance to reduce the duration of in-hospital surveillance. What is Known: • Minor head trauma can cause clinically important traumatic brain injury in infants, and the management of these cases is a challenge for the treating physician. • Cranial ultrasound (CUS) is regularly used in neonatology, but its accuracy after head trauma in infants is controversial. What is New: • CUS performed by a trained radiologist can exclude findings related to clinically important traumatic brain injury (ciTBI) with high sensitivity and specificity. It therefore offers reassurance in the management of infants after minor head trauma

    Artificial Intelligence and Interstitial Lung Disease: Diagnosis and Prognosis.

    Get PDF
    Interstitial lung disease (ILD) is now diagnosed by an ILD-board consisting of radiologists, pulmonologists, and pathologists. They discuss the combination of computed tomography (CT) images, pulmonary function tests, demographic information, and histology and then agree on one of the 200 ILD diagnoses. Recent approaches employ computer-aided diagnostic tools to improve detection of disease, monitoring, and accurate prognostication. Methods based on artificial intelligence (AI) may be used in computational medicine, especially in image-based specialties such as radiology. This review summarises and highlights the strengths and weaknesses of the latest and most significant published methods that could lead to a holistic system for ILD diagnosis. We explore current AI methods and the data use to predict the prognosis and progression of ILDs. It is then essential to highlight the data that holds the most information related to risk factors for progression, e.g., CT scans and pulmonary function tests. This review aims to identify potential gaps, highlight areas that require further research, and identify the methods that could be combined to yield more promising results in future studies

    Influence of Lung Reconstruction Algorithms on Interstitial Lung Pattern Recognition on CT.

    Get PDF
    BACKGROUND  Despite current recommendations, there is no recent scientific study comparing the influence of CT reconstruction kernels on lung pattern recognition in interstitial lung disease (ILD). PURPOSE  To evaluate the sensitivity of lung (i70) and soft (i30) CT kernel algorithms for the diagnosis of ILD patterns. MATERIALS AND METHODS  We retrospectively extracted between 15-25 pattern annotations per case (1 annotation = 15 slices of 1 mm) from 23 subjects resulting in 408 annotation stacks per lung kernel and soft kernel reconstructions. Two subspecialized chest radiologists defined the ground truth in consensus. 4 residents, 2 fellows, and 2 general consultants in radiology with 3 to 13 years of experience in chest imaging performed a blinded readout. In order to account for data clustering, a generalized linear mixed model (GLMM) with random intercept for reader and nested for patient and image and a kernel/experience interaction term was used to analyze the results. RESULTS  The results of the GLMM indicated, that the odds of correct pattern recognition is 12 % lower with lung kernel compared to soft kernel; however, this was not statistically significant (OR 0.88; 95%-CI, 0.73-1.06; p = 0.187). Furthermore, the consultants' odds of correct pattern recognition was 78 % higher than the residents' odds, although this finding did not reach statistical significance either (OR 1.78; 95%-CI, 0.62-5.06; p = 0.283). There was no significant interaction between the two fixed terms kernel and experience. Intra-rater agreement between lung and soft kernel was substantial (κ = 0.63 ± 0.19). The mean inter-rater agreement for lung/soft kernel was κ = 0.37 ± 0.17/κ = 0.38 ± 0.17. CONCLUSION  There is no significant difference between lung and soft kernel reconstructed CT images for the correct pattern recognition in ILD. There are non-significant trends indicating that the use of soft kernels and a higher level of experience lead to a higher probability of correct pattern identification. KEY POINTS   · There is no significant difference between lung and soft kernel reconstructed CT images for the correct pattern recognition in interstitial lung disease.. · There are even non-significant tendencies that the use of soft kernels lead to a higher probability of correct pattern identification.. · These results challenge the current recommendations and the routinely performed separate lung kernel reconstructions for lung parenchyma analysis.. CITATION FORMAT · Klaus JB, Christodoulidis S, Peters AA et al. Influence of Lung Reconstruction Algorithms on Interstitial Lung Pattern Recognition on CT. Fortschr Röntgenstr 2022; DOI: 10.1055/a-1901-7814

    The Swiss Approach - feasibility of a national low-dose CT lung cancer screening program.

    Get PDF
    BACKGROUND Lung cancer is the leading cause of cancer-related deaths in Switzerland. Despite this, there is no lung cancer screening program in the country. In the United States, low-dose computed tomography (LDCT) lung cancer screening is partially established and endorsed by guidelines. Moreover, evidence is growing that screening reduces lung cancer-related mortality and this was recently shown in a large European randomized controlled trial. Implementation of a lung cancer screening program, however, is challenging and depends on many country-specific factors. The goal of this article is to outline a potential Swiss lung cancer screening program. FRAMEWORK An exhaustive literature review on international screening models as well as interviews and site visits with international experts were initiated. Furthermore, workshops and interviews with national experts and stakeholders were conducted to share experiences and to establish the basis for a national Swiss lung cancer screening program. SCREENING APPROACH General practitioners, pulmonologists and the media should be part of the recruitment process. Decentralisation of the screening might lead to a higher adherence rate. To reduce stigmatisation, the screening should be integrated in a "lung health check". Standardisation and a common quality level are mandatory. The PLCOm2012 risk calculation model with a threshold of 1.5% risk for developing cancer in the next six years should be used in addition to established inclusion criteria. Biennial screening is preferred. LUNG RADS and NELSON+ are applied as classification models for lung nodules. CONCLUSION Based on data from recent studies, literature research, a health technology assessment, the information gained from this project and a pilot study the Swiss Interest Group for lung cancer screening (CH-LSIG) recommends the timely introduction of a systematic lung cancer screening program in Switzerland. The final decision is for the Swiss Cancer Screening Committee to make

    The Swiss Approach - feasibility of a national low-dose CT lung cancer screening program

    Full text link
    BACKGROUND Lung cancer is the leading cause of cancer-related deaths in Switzerland. Despite this, there is no lung cancer screening program in the country. In the United States, low-dose computed tomography (LDCT) lung cancer screening is partially established and endorsed by guidelines. Moreover, evidence is growing that screening reduces lung cancer-related mortality and this was recently shown in a large European randomized controlled trial. Implementation of a lung cancer screening program, however, is challenging and depends on many country-specific factors. The goal of this article is to outline a potential Swiss lung cancer screening program. FRAMEWORK An exhaustive literature review on international screening models as well as interviews and site visits with international experts were initiated. Furthermore, workshops and interviews with national experts and stakeholders were conducted to share experiences and to establish the basis for a national Swiss lung cancer screening program. SCREENING APPROACH General practitioners, pulmonologists and the media should be part of the recruitment process. Decentralisation of the screening might lead to a higher adherence rate. To reduce stigmatisation, the screening should be integrated in a "lung health check". Standardisation and a common quality level are mandatory. The PLCOm2012 risk calculation model with a threshold of 1.5% risk for developing cancer in the next six years should be used in addition to established inclusion criteria. Biennial screening is preferred. LUNG RADS and NELSON+ are applied as classification models for lung nodules. CONCLUSION Based on data from recent studies, literature research, a health technology assessment, the information gained from this project and a pilot study the Swiss Interest Group for lung cancer screening (CH-LSIG) recommends the timely introduction of a systematic lung cancer screening program in Switzerland. The final decision is for the Swiss Cancer Screening Committee to make

    Electrospun PLLA Nanofiber Scaffolds and Their Use in Combination with BMP-2 for Reconstruction of Bone Defects

    Get PDF
    Introduction Adequate migration and differentiation of mesenchymal stem cells is essential for regeneration of large bone defects. To achieve this, modern graft materials are becoming increasingly important. Among them, electrospun nanofiber scaffolds are a promising approach, because of their high physical porosity and potential to mimic the extracellular matrix (ECM). Materials and Methods The objective of the present study was to examine the impact of electrospun PLLA nanofiber scaffolds on bone formation in vivo, using a critical size rat calvarial defect model. In addition we analyzed whether direct incorporation of bone morphogenetic protein 2 (BMP-2) into nanofibers could enhance the osteoinductivity of the scaffolds. Two critical size calvarial defects (5 mm) were created in the parietal bones of adult male Sprague-Dawley rats. Defects were either (1) left unfilled, or treated with (2) bovine spongiosa, (3) PLLA scaffolds alone or (4) PLLA/BMP-2 scaffolds. Cranial CT-scans were taken at fixed intervals in vivo. Specimens obtained after euthanasia were processed for histology, histomorphometry and immunostaining (Osteocalcin, BMP-2 and Smad5). Results PLLA scaffolds were well colonized with cells after implantation, but only showed marginal ossification. PLLA/BMP-2 scaffolds showed much better bone regeneration and several ossification foci were observed throughout the defect. PLLA/BMP-2 scaffolds also stimulated significantly faster bone regeneration during the first eight weeks compared to bovine spongiosa. However, no significant differences between these two scaffolds could be observed after twelve weeks. Expression of osteogenic marker proteins in PLLA/BMP-2 scaffolds continuously increased throughout the observation period. After twelve weeks osteocalcin, BMP-2 and Smad5 were all significantly higher in the PLLA/BMP-2 group than in all other groups. Conclusion Electrospun PLLA nanofibers facilitate colonization of bone defects, while their use in combination with BMP-2 also increases bone regeneration in vivo and thus combines osteoconductivity of the scaffold with the ability to maintain an adequate osteogenic stimulus
    corecore